Manually operated microtube automatic capper/decapper system for clinical laboratory and biological laboratory personnel
ROBOMECH Journal, ISSN: 2197-4225, Vol: 11, Issue: 1
2024
- 3Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures3
- Readers3
- Mentions1
- News Mentions1
- 1
Most Recent News
Data from Kokushikan University Broaden Understanding of Coronavirus (Manually operated microtube automatic capper/decapper system for clinical laboratory and biological laboratory personnel)
2024 OCT 14 (NewsRx) -- By a News Reporter-Staff News Editor at CDC & FDA Daily -- Researchers detail new data in coronavirus. According to
Article Description
Polymerase chain reaction (PCR) is an effective method for diagnosing infectious diseases and has been the primary method throughout the novel coronavirus disease (COVID-19) pandemic. PCR tests (from specimen collection to result acquisition) involve sample pretreatment, nucleic acid extraction, and PCR procedure. Automating the pretreatment process is crucial to mitigate the risk of infection for workers and to reduce the likelihood of sample contamination-triggered misdiagnosis, particularly when handling centrifuge tubes, cryopreservation tubes, and microtubes. Robotic systems have been engineered to automate cell culture and PCR-based diagnosis, predominantly designed for use with screw-capped containers. However, this leaves a notable gap in automation solutions for microtubes equipped with press-type caps. To address this gap, we developed a versatile microtube capper/decapper system. On the other hand, many tasks of manual operation using microtubes, which are routinely conducted in clinical tests and biological experiments, are performed. Compared to screw-type caps for centrifuge and cryopreservation tubes, press-type caps for microtubes present a considerably higher risk of the worker's fingers contacting the inside of the cap and/or generating airborne droplets. Despite the risks of contamination and infection derived from the manual handling of microtube caps, which can compromise diagnosis/experiment accuracy and worker safety, devices for manually opening and closing microtube caps without direct contact remain lacking. Therefore, leveraging the technology from the developed versatile microtube capper/decapper system for laboratory automation, we created a manually operated microtube equipped with an automatic capper/decapper system tailored for personnel in clinical and biological laboratories. In this study, we first examined the required specifications and prerequisites for a manual microtube capper/decapper and clarified the operating methods, operating procedures, operation environment, device size, accompanying functions, etc. Based on the required specifications and preconditions, we proceeded with the mechanical and control design of the conceptual model, manufactured a prototype, and confirmed its basic functions and performance. The compliant to the required specifications and preconditions and the usefulness of the proposed manual microtube capper/decapper were validated through various experiments and demonstrations. Using the proposed microtube capper/decapper, even small-scale operations, which are challenging to streamline, can be performed nearly as efficiently as full manual operations. Although operation time was not reduced, the ability to open and close microtubes without manual contact is crucial for improving diagnostic and experimental accuracy and for reducing the burden on and enhancing the safety of laboratory personnel. Because microtubes are used in various clinical tests and biological experiments, we believe that the proposed system can markedly reduce the workload for personnel across numerous clinical and biological laboratories.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know