PlumX Metrics
Embed PlumX Metrics

Dimensional accuracy and precision and surgeon perception of additively manufactured bone models: effect of manufacturing technology and part orientation

3D Printing in Medicine, ISSN: 2365-6271, Vol: 10, Issue: 1, Page: 5
2024
  • 3
    Citations
  • 0
    Usage
  • 16
    Captures
  • 0
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

  • Citations
    3
    • Citation Indexes
      3
  • Captures
    16

Article Description

Background: Additively manufactured (AM) anatomical bone models are primarily utilized for training and preoperative planning purposes. As such, they must meet stringent requirements, with dimensional accuracy being of utmost importance. This study aimed to evaluate the precision and accuracy of anatomical bone models manufactured using three different AM technologies: digital light processing (DLP), fused deposition modeling (FDM), and PolyJetting (PJ), built in three different part orientations. Additionally, the study sought to assess surgeons’ perceptions of how well these models mimic real bones in simulated osteosynthesis. Methods: Computer-aided design (CAD) models of six human radii were generated from computed tomography (CT) imaging data. Anatomical models were then manufactured using the three aforementioned technologies and in three different part orientations. The surfaces of all models were 3D-scanned and compared with the original CAD models. Furthermore, an anatomical model of a proximal femur including a metastatic lesion was manufactured using the three technologies, followed by (mock) osteosynthesis performed by six surgeons on each type of model. The surgeons’ perceptions of the quality and haptic properties of each model were assessed using a questionnaire. Results: The mean dimensional deviations from the original CAD model ranged between 0.00 and 0.13 mm with maximal inaccuracies < 1 mm for all models. In surgical simulation, PJ models achieved the highest total score on a 5-point Likert scale ranging from 1 to 5 (with 1 and 5 representing the lowest and highest level of agreement, respectively), (3.74 ± 0.99) in the surgeons’ perception assessment, followed by DLP (3.41 ± 0.99) and FDM (2.43 ± 1.02). Notably, FDM was perceived as unsuitable for surgical simulation, as the material melted during drilling and sawing. Conclusions: In conclusion, the choice of technology and part orientation significantly influenced the accuracy and precision of additively manufactured bone models. However, all anatomical models showed satisfying accuracies and precisions, independent of the AM technology or part orientation. The anatomical and functional performance of FDM models was rated by surgeons as poor.

Bibliographic Details

Benca, Emir; Eckhart, Barbara; Stoegner, Alexander; Unger, Ewald; Bittner-Frank, Martin; Strassl, Andreas; Gahleitner, Claudia; Hirtler, Lena; Windhager, Reinhard; Hobusch, Gerhard M; Moscato, Francesco

Springer Science and Business Media LLC

Engineering; Medicine; Computer Science

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know