The clinical value of xSPECT/CT Bone versus SPECT/CT. A prospective comparison of 200 scans
European Journal of Hybrid Imaging, ISSN: 2510-3636, Vol: 2, Issue: 1, Page: 4
2018
- 29Citations
- 27Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations29
- Citation Indexes29
- 29
- Captures27
- Readers27
- 27
Article Description
Purpose: To prospectively evaluate the clinical utility of xSPECT/CT Bone, a new reconstruction algorithm for single photon emission tomography (SPECT), and compare it with standard SPECT/CT reconstruction. Methods: Sequential reporting of SPECT/CT followed by xSPECT/CT images in 200 sequential cases commencing August 2015. Differences between the initial SPECT/CT and the final report (after xSPECT/CT reconstruction) were documented and analysed. 12–18 months after the initial study follow-up, clinical data was sought from a subset of cases in which xSPECT/CT changed the primary diagnosis and imaging correlation undertaken in all patients who subsequently had MRI or CT scans of the same region. Results: A majority of the 200 cases were related to assessment of musculoskeletal complaints. The final (scan) diagnosis was changed after reviewing the xSPECT/CT images in 40 (20%) of cases. The reporting physician (Iain Duncan) assessed that the xSPECT/CT had provided more diagnostic information in 71% of cases. A total of 470 additional lesions were found, equivalent to 2.4 lesions per case. In 33 cases of imaging follow-up there was a high degree of correlation with bone scan findings and xSPECT correlated better than SPECT in regard to detailed findings. In only 15/40 cases of diagnostic change could the outcome be verified and in 12/15 the xSPECT/CT revised diagnosis was confirmed. Conclusions: In this observational evaluation xSPECT/CT Bone reconstruction offers identifiable imaging improvements over standard SPECT/CT reconstruction algorithms. xSPECT/CT Bone provides an improvement in diagnostic confidence and identifies a greater number of lesions.
Bibliographic Details
Springer Nature
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know