Development of invitro blood vessel coagulation-incision experimental method and characterization of opposite-phase vibration type ultrasonic scalpel
Journal of Advanced Mechanical Design, Systems and Manufacturing, ISSN: 1881-3054, Vol: 17, Issue: 4, Page: JAMDSM0049-JAMDSM0049
2023
- 1Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures1
- Readers1
Article Description
The ultrasonic scalpel used in the operation can perform coagulation hemostasis and tissue incision in the affected area. For coagulation, thermal denaturation must be completed before incision. Improvement of coagulation performance is required to shorten the operation time. The ultrasonic scalpels used were opposite-phase vibration modes with scissors like ultrasonic vibration modes proposed by our research group. Since the opposite-phase vibration vibrates in a direction vertical to an axis in addition to the longitudinal vibration of a normal ultrasonic scalpel, it is expected to improve coagulation performance due to heat generation by rubbing while pressing. In this research, a method for evaluating the coagulation performance of blood vessels that had been coagulated and incised with an ultrasonic scalpel was investigated. As a result, stress-strain curve results were obtained by using the experimental methods examined, and the strength of coagulation could be evaluated. In addition, characteristics of scalpel were evaluated by comparison of coagulation performance under different incision conditions.
Bibliographic Details
Japan Society of Mechanical Engineers
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know