Passive spectroscopy in visible, VUV, and X-ray ranges for LHD diagnostics
Fusion Science and Technology, ISSN: 1536-1055, Vol: 58, Issue: 1, Page: 394-411
2010
- 20Citations
- 4Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Various types of spectrometers corresponding to different wavelength ranges from X-ray to visible have been developed for the Large Helical Device (LHD). The charge-coupled device is demonstrated to be a suitable solution as a detector for spectral measurements irrespective of the wavelength range. In the ultraviolet (UV)-visible range, an astigmatism-corrected 1.3-m Czerny-Turner-type spectrometer is developed for a simultaneous measurement with 80 lines of sight. Two other]UV-visible spectrometers having focal lengths of 0.3 and 0.5 m, respectively, are also prepared for wide wavelength range measurements. An in situ sensitivity calibration is attempted for these spectrometers, for which visible bremsstrahlung from the LHD plasma is utilized. In the vacuum ultraviolet range (30 to 310 nm), a normal incidence spectrometer having a focal length of 3 m is developed for a spatial intensity profile measurement of impurity ions, especially in the plasma boundary region, and for measurements of line broadening of several impurity ions. A number of forbidden emission lines due to magnetic dipole transitions are also identified with this spectrometer. In the extreme ultraviolet range (1 to 50 nm), flat-field spectrometers are developed for measurements of emission lines from high-Z impurities in the plasma core. Two types of gratings, i.e., mechanically ruled and laminar-type holographic, have been tested, and the latter is found to be preferable with respect to the reflectivity and the resolution power. A Johann-type X-ray crystal spectrometer is developed for measurements of the central ion temperature, for which the resonance line of Ar XVII ion (Is 5 - Is2pP) is mainly used. The central ion temperature is routinely measured with high time resolution.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know