Image quality in time-resolved transillumination of highly scattering media
Applied Optics, ISSN: 2155-3165, Vol: 34, Issue: 27, Page: 6144-6157
1995
- 30Citations
- 14Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Using a photon-counting setup and a streak-camera arrangement with time resolutions of 35 and 6 ps, respectively, we have investigated the spatial resolution of a time-gated transillumination technique applied to turbid media. In the case of large relative amounts of unscattered light, it is found that small detection angles improve the spatial resolution. For large concentrations of scatterers and large sample thicknesses, i.e., when the amount of unscattered light is negligible, the best time-gate position is found to be at times that are later than the minimum transit time. In this case (minimum transit time), temporal resolutions from small values up to approximately 50 ps yield almost the same image resolution. The only advantage of measuring systems with a higher than 50-ps temporal resolution is their ability to distinguish the diffused from the unscattered light, when a significant amount of the latter is present. © 1995 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0001687076&origin=inward; http://dx.doi.org/10.1364/ao.34.006144; http://www.ncbi.nlm.nih.gov/pubmed/21060456; https://www.osapublishing.org/abstract.cfm?URI=ao-34-27-6144; https://www.osapublishing.org/viewmedia.cfm?URI=ao-34-27-6144&seq=0; https://opg.optica.org/abstract.cfm?URI=ao-34-27-6144; https://dx.doi.org/10.1364/ao.34.006144; https://opg.optica.org/ao/abstract.cfm?uri=ao-34-27-6144
The Optical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know