Noise-enhanced measurement of weak doublet spectra with a Fourier-transform spectrometer and a 1-bit analog-to-digital converter
Applied Optics, ISSN: 2155-3165, Vol: 40, Issue: 11, Page: 1767-1775
2001
- 3Citations
- 10Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We demonstrate an efficient noise dithering procedure for measuring the power spectrum of a weak spectral doublet with a Fourier-transform spectrometer in which the subthreshold interferogram is measured by a 1-bit analog-to-digital converter without oversampling. In the absence of noise, no information is obtained regarding the doublet spectrum because the modulation term s~x! of its interferogram is below the instrumental detection limit B, i.e., us~x!u, B, for all path difference x values. Extensive numerical experiments are carried out concerning the recovery of the doublet power spectrum that is represented by s(x) = (s/2)exp(-πx/β)[cos(2πfx)+cos(2πfx)], where s is a constant, b is the linewidth factor, and ⟨f⟩ =(f + f]/2. Different values of ⟨f⟩, s, and β are considered to evaluate thoroughly the accuracy of the procedure to determine the unknown values of f and f, the spectral linewidth, and the peak values of the spectral profiles. Our experiments show that, even for short observation times, the resonant frequencies of s(x) could be located with high accuracy over a wide range of ⟨f⟩ and β values. Signal-to-noise ratios as high as 50 are also gained for the recovered power spectra. The performance of the procedure is also analyzed with respect to another method that recovers the amplitude values of s(x) directly. © 2001 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0037825920&origin=inward; http://dx.doi.org/10.1364/ao.40.001767; http://www.ncbi.nlm.nih.gov/pubmed/18357174; https://www.osapublishing.org/abstract.cfm?URI=ao-40-11-1767; https://www.osapublishing.org/viewmedia.cfm?URI=ao-40-11-1767&seq=0; https://opg.optica.org/abstract.cfm?URI=ao-40-11-1767; https://dx.doi.org/10.1364/ao.40.001767; https://opg.optica.org/ao/abstract.cfm?uri=ao-40-11-1767
The Optical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know