Dynamic performance of a membrane-based variable focus lens with a large aperture
Applied Optics, ISSN: 2155-3165, Vol: 62, Issue: 17, Page: 4609-4617
2023
- 2Citations
- 6Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Dynamic performance is one of the most important characteristics of a variable focus lens. However, there are few studies investigating the dynamic response of a membrane-based variable focus lens. In this paper, we present a mathematical model to describe spring-damping phenomena in theory. The first order natural frequencies with different scales were confirmed via finite element analysis.We also built a dynamic response experiment platform with changeable optical apertures, which was driven by a high-speed piezo stack actuator. A photodiode module was placed behind the lens to measure the variation of light luminance as the lens changed, and a laser displacement sensor was used to measure the deformation of the membrane. A series of data was collected with different optical apertures (20 mm, 30 mm, 50 mm) and different pre-stretching ratios (200%, 300%) under different driving frequencies (from 5 Hz to 25 Hz in every 5 Hz step). The experimental results were consistent with the mathematical model, which showed that the first order natural frequency increased as the aperture decreased or the membrane stiffness increased. This frequency-dependent characteristic of the variable focus lens provides a basis for further research on its dynamic performance.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85164921285&origin=inward; http://dx.doi.org/10.1364/ao.486278; http://www.ncbi.nlm.nih.gov/pubmed/37707158; https://opg.optica.org/abstract.cfm?URI=ao-62-17-4609; https://dx.doi.org/10.1364/ao.486278; https://opg.optica.org/ao/abstract.cfm?uri=ao-62-17-4609
Optica Publishing Group
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know