Handheld probe for quantitative micro-elastography
Biomedical Optics Express, ISSN: 2156-7085, Vol: 10, Issue: 8, Page: 4034-4049
2019
- 27Citations
- 26Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations27
- Citation Indexes25
- 25
- CrossRef7
- Policy Citations2
- 2
- Captures26
- Readers26
- 26
Article Description
Optical coherence elastography (OCE) has been proposed for a range of clinical applications. However, the majority of these studies have been performed using bulky, lab-based imaging systems. A compact, handheld imaging probe would accelerate clinical translation, however, to date, this had been inhibited by the slow scan rates of compact devices and the motion artifact induced by the user’s hand. In this paper, we present a proof-of-concept, handheld quantitative micro-elastography (QME) probe capable of scanning a 6 × 6 × 1 mm volume of tissue in 3.4 seconds. This handheld probe is enabled by a novel QME acquisition protocol that incorporates a custom bidirectional scan pattern driving a microelectromechanical system (MEMS) scanner, synchronized with the sample deformation induced by an annular PZT actuator. The custom scan pattern reduces the total acquisition time and the time difference between B-scans used to generate displacement maps, minimizing the impact of motion artifact. We test the feasibility of the handheld QME probe on a tissue-mimicking silicone phantom, demonstrating comparable image quality to a bench-mounted setup. In addition, we present the first handheld QME scans performed on human breast tissue specimens. For each specimen, quantitative micro-elastograms are co-registered with, and validated by, histology, demonstrating the ability to distinguish stiff cancerous tissue from surrounding soft benign tissue.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85070944318&origin=inward; http://dx.doi.org/10.1364/boe.10.004034; http://www.ncbi.nlm.nih.gov/pubmed/31452993; https://opg.optica.org/abstract.cfm?URI=boe-10-8-4034; https://dx.doi.org/10.1364/boe.10.004034; https://opg.optica.org/boe/fulltext.cfm?uri=boe-10-8-4034&id=415545; https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-8-4034; https://opg.optica.org/abstract.cfm?uri=boe-10-8-4034; https://opg.optica.org/viewmedia.cfm?uri=boe-10-8-4034&seq=0&html=true; https://opg.optica.org/viewmedia.cfm?uri=boe-10-8-4034&seq=0; https://opg.optica.org/boe/abstract.cfm?uri=boe-10-8-4034; https://research-repository.uwa.edu.au/en/publications/handheld-probe-for-quantitative-microelastography(7fdc5811-6f49-47fa-8a04-2dacb9388b33).html; https://research-repository.uwa.edu.au/en/publications/handheld-probe-for-quantitative-micro-elastography; https://www.osapublishing.org/abstract.cfm?URI=boe-10-8-4034; http://research-repository.uwa.edu.au/en/publications/handheld-probe-for-quantitative-microelastography(7fdc5811-6f49-47fa-8a04-2dacb9388b33).html; https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-10-8-4034&id=415545
The Optical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know