Quantitation of cerebral oxygen tension using phasor analysis and phosphorescence lifetime imaging microscopy (PLIM)
Biomedical Optics Express, ISSN: 2156-7085, Vol: 12, Issue: 7, Page: 4192-4206
2021
- 2Citations
- 4Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Time-domain measurements for fluorescence lifetime imaging microscopy (FLIM) and phosphorescence lifetime imaging microscopy (PLIM) are conventionally computed by nonlinear curve fitting techniques to model the time-resolved profiles as mono- or multiexponential decays. However, these techniques are computationally intensive and prone to fitting errors. The phasor or “polar plot” analysis method has recently gained attention as a simple method to characterize fluorescence lifetime. Here, we adapted the phasor analysis method for absolute quantitation of phosphorescence lifetimes of oxygen-sensitive phosphors and used the phasor-derived lifetime values to quantify oxygen partial pressure (pO2) in cortical microvessels of awake mice. Our results, both experimental and simulated, demonstrate that oxygen measurements obtained from computationally simpler phasor analysis agree well with traditional curve fitting calculations. To our knowledge, the current study constitutes the first application of the technique for characterizing microsecond-length, time-domain phosphorescence measurements and absolute, in vivo quantitation of a vital physiological parameter. The method shows promise for monitoring cerebral metabolism and pathological changes in preclinical rodent models.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85108291315&origin=inward; http://dx.doi.org/10.1364/boe.428873; http://www.ncbi.nlm.nih.gov/pubmed/34457408; https://opg.optica.org/abstract.cfm?URI=boe-12-7-4192; https://dx.doi.org/10.1364/boe.428873; https://opg.optica.org/boe/fulltext.cfm?uri=boe-12-7-4192&id=452113