Fiber-based polarization-sensitive OCT of the human retina with correction of system polarization distortions
Biomedical Optics Express, ISSN: 2156-7085, Vol: 5, Issue: 8, Page: 2736-2758
2014
- 71Citations
- 82Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations71
- Citation Indexes71
- 71
- CrossRef66
- Captures82
- Readers82
- 82
Article Description
In polarization-sensitive optical coherence tomography (PSOCT) the use of single-mode fibers causes unpredictable polarization distortions which can result in increased noise levels and erroneous changes in calculated polarization parameters. In the current paper this problem is addressed by a new Jones matrix analysis method that measures and corrects system polarization distortions as a function of wavenumber by spectral analysis of the sample surface polarization state and deeper located birefringent tissue structures. This method was implemented on a passivecomponent depth-multiplexed swept-source PS-OCT system at 1040 nm which was theoretically modeled using Jones matrix calculus. Highresolution B-scan images are presented of the double-pass phase retardation, diattenuation, and relative optic axis orientation to show the benefits of the new analysis method for in vivo imaging of the human retina. The correction of system polarization distortions yielded reduced phase retardation noise, and better estimates of the diattenuation and the relative optic axis orientation in weakly birefringent tissues. The clinical potential of the system is shown by en face visualization of the phase retardation and optic axis orientation of the retinal nerve fiber layer in a healthy volunteer and a glaucoma patient with nerve fiber loss. © 2014 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84904657617&origin=inward; http://dx.doi.org/10.1364/boe.5.002736; http://www.ncbi.nlm.nih.gov/pubmed/25136498; https://opg.optica.org/boe/abstract.cfm?uri=boe-5-8-2736; https://www.osapublishing.org/boe/abstract.cfm?uri=boe-5-8-2736; https://www.osapublishing.org/viewmedia.cfm?URI=boe-5-8-2736&seq=0; https://dx.doi.org/10.1364/boe.5.002736; https://opg.optica.org/boe/fulltext.cfm?uri=boe-5-8-2736&id=297031; https://opg.optica.org/abstract.cfm?uri=boe-5-8-2736; https://opg.optica.org/viewmedia.cfm?uri=boe-5-8-2736&seq=0&html=true; https://opg.optica.org/viewmedia.cfm?uri=boe-5-8-2736&seq=0; http://www.opticsinfobase.org/abstract.cfm?URI=boe-5-8-2736; https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-5-8-2736&id=297031