13.2 W laser-diode-pumped Nd:YVO4 /LBO blue laser at 457 nm
Journal of the Optical Society of America B: Optical Physics, ISSN: 0740-3224, Vol: 26, Issue: 6, Page: 1238-1242
2009
- 98Citations
- 26Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We report the efficient compact deep-blue laser at 457 nm generation by intracavity frequency doubling of a continuous wave (cw) laser operation of a diode-pumped Nd:YVO4 laser on the F?I transition at 914 nm. An LBO crystal, cut for critical type I phase matching at room temperature is used for secondharmonic generation (SHG) of the laser. At an incident pump power of 38 W, as high as 13.2 W of cw output power at 457 nm is achieved with 15-mm-long LBO. The optical-to-optical conversion efficiency is up to 34.7%, and the power stability in 2 h is better than ±2.68%. ©2009 Optical Society of America ©2009 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=67650742107&origin=inward; http://dx.doi.org/10.1364/josab.26.001238; https://opg.optica.org/abstract.cfm?URI=josab-26-6-1238; https://www.osapublishing.org/abstract.cfm?URI=josab-26-6-1238; https://www.osapublishing.org/viewmedia.cfm?URI=josab-26-6-1238&seq=0; https://dx.doi.org/10.1364/josab.26.001238; https://opg.optica.org/josab/abstract.cfm?uri=josab-26-6-1238
Optica Publishing Group
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know