Optimizing the time resolution of supercontinuum spectral interferometry
Journal of the Optical Society of America B: Optical Physics, ISSN: 1520-8540, Vol: 33, Issue: 7, Page: 1476-1481
2016
- 26Citations
- 28Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Single-shot supercontinuum spectral interferometry is a powerful technique for measuring transient refractive index changes. In principle, its time resolution is limited only by the available probe bandwidth. However, this assumes that the phase extraction has sufficient spectral resolution and that the probe spectral phase is exactly known. Using an analytical model for the spectral phase and amplitude modulation of a chirped probe pulse by a weak transient phase perturbation, we show how the probe chirp and spectral resolution determine the achievable time resolution. A simple, practical technique for precise in situ measurement of the probe spectral phase is described in detail, and the sensitivity of the extracted temporal phase profile to uncertainty in the probe spectral phase is demonstrated in numerical simulations.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84978204103&origin=inward; http://dx.doi.org/10.1364/josab.33.001476; https://www.osapublishing.org/abstract.cfm?URI=josab-33-7-1476; https://www.osapublishing.org/viewmedia.cfm?URI=josab-33-7-1476&seq=0; https://www.osapublishing.org/viewmedia.cfm?URI=josab-33-7-1476&am=y; https://opg.optica.org/abstract.cfm?URI=josab-33-7-1476; https://dx.doi.org/10.1364/josab.33.001476; https://opg.optica.org/josab/abstract.cfm?uri=josab-33-7-1476
The Optical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know