Microscopy with microlens arrays: High throughput, high resolution and light-field imaging
Optics Express, ISSN: 1094-4087, Vol: 20, Issue: 12, Page: 13522-13531
2012
- 90Citations
- 116Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations90
- Citation Indexes86
- 86
- CrossRef77
- Patent Family Citations4
- Patent Families4
- Captures116
- Readers116
- 116
Article Description
We demonstrate highly parallelized fluorescence scanning microscopy using a refractive microlens array. Fluorescent beads and rat femur tissue are imaged over a 5.5 mm x 5.5 mm field of view at a pixel throughput of up to 4 megapixels/s and a resolution of 706 nm. We also demonstrate the ability to extract different perspective views of a pile of microspheres. ©2012 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84863760674&origin=inward; http://dx.doi.org/10.1364/oe.20.013522; http://www.ncbi.nlm.nih.gov/pubmed/22714379; https://www.osapublishing.org/oe/abstract.cfm?uri=oe-20-12-13522&tab=supplmat; http://dx.doi.org/10.1364/oe.20.013522.m001; https://opg.optica.org/oe/abstract.cfm?uri=oe-20-12-13522&tab=supplmat; https://www.osapublishing.org/abstract.cfm?URI=oe-20-12-13522; https://www.osapublishing.org/viewmedia.cfm?URI=oe-20-12-13522&seq=0; https://opg.optica.org/abstract.cfm?URI=oe-20-12-13522; https://dx.doi.org/10.1364/oe.20.013522.m001; https://opg.optica.org/oe/fulltext.cfm?uri=oe-20-12-13522&id=236616; https://dx.doi.org/10.1364/oe.20.013522; https://opg.optica.org/abstract.cfm?uri=oe-20-12-13522; https://opg.optica.org/viewmedia.cfm?uri=oe-20-12-13522&seq=0&html=true; https://opg.optica.org/viewmedia.cfm?uri=oe-20-12-13522&seq=0; https://opg.optica.org/oe/abstract.cfm?uri=oe-20-12-13522; http://www.opticsinfobase.org/abstract.cfm?URI=oe-20-12-13522; https://www.osapublishing.org/oe/abstract.cfm?uri=oe-20-12-13522; https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-20-12-13522&id=236616
The Optical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know