Optics-mechanics synergistic fiber optic sensor for hydrogen detection
Optics Express, ISSN: 1094-4087, Vol: 30, Issue: 18, Page: 32769-32782
2022
- 6Citations
- 2Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
As a carbon-free energy carrier and an attractive alternative energy source, hydrogen energy has great development potential for future considerations, and it may be the ultimate answer to the global energy crisis. Due to the high combustibility of hydrogen, hydrogen sensors will be a vital component of safe use of hydrogen. Among the various sensors, the optical hydrogen sensor can meet the requirements of intrinsic safety, online detection, surrounding immunity, and lack of spark. Hence, we demonstrate a miniature optics-mechanics synergistic fiber optic hydrogen sensor by using Pd nanofilm, it has a large response range (0.5%-3.5%), high sensitivity of -0.334 nm/1% concentration and a short response time (10s)/recovery time (25s). Experimental results reveal that the proposed optics-mechanics synergistic fiber optic hydrogen sensor is reusable, durable, and low temperature sensitive. In this optics-mechanics synergistic fiber optic hydrogen sensor, nano Pd film with a large surface-to-volume ratio allows for rapid hydrogen dissociation, and Pd lattice expansion caused by Pd-hydrogen reaction is effectively transduced into optical change. This proposed sensor integrated Pd nanofilm with optical fiber by using an optics-mechanics synergistic strategy, resulting in a compact and all-optical solution for the safe measurement of hydrogen concentration, which can be used in hazardous or space-limited environments.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85137132891&origin=inward; http://dx.doi.org/10.1364/oe.468282; http://www.ncbi.nlm.nih.gov/pubmed/36242332; https://opg.optica.org/abstract.cfm?URI=oe-30-18-32769; https://dx.doi.org/10.1364/oe.468282; https://opg.optica.org/oe/abstract.cfm?uri=oe-30-18-32769
Optica Publishing Group
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know