Ultrasensitive and high-dynamic-range two-photon absorption in a GaAs photomultiplier tube
Optics Letters, ISSN: 0146-9592, Vol: 27, Issue: 23, Page: 2076-2078
2002
- 109Citations
- 83Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations109
- Citation Indexes109
- 109
- CrossRef80
- Captures83
- Readers83
- 83
Article Description
We demonstrate improved efficiency and dynamic range for two-photon absorption at 1.5 μm in a photoelectron-counting GaAs photomultiplier tube. cw laser measurements show pure two-photon absorption occurring in the device from average powers of 1.3 μW to nearly 1 mW. We use the detector to implement an autocorrelator with peak-power × average-power sensitivity of 1.7 × 10 (mW) and discuss practical ways to reduce this figure of merit to as low as 1 × 10 (mW). © 2002 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0036918502&origin=inward; http://dx.doi.org/10.1364/ol.27.002076; http://www.ncbi.nlm.nih.gov/pubmed/18033446; https://www.osapublishing.org/abstract.cfm?URI=ol-27-23-2076; https://www.osapublishing.org/viewmedia.cfm?URI=ol-27-23-2076&seq=0; https://opg.optica.org/abstract.cfm?URI=ol-27-23-2076; https://dx.doi.org/10.1364/ol.27.002076; https://opg.optica.org/ol/abstract.cfm?uri=ol-27-23-2076
The Optical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know