Adaptive aberration correction of GRIN lenses for confocal endomicroscopy
Optics Letters, ISSN: 1539-4794, Vol: 36, Issue: 23, Page: 4608-4610
2011
- 38Citations
- 68Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations38
- Citation Indexes38
- CrossRef38
- 37
- Captures68
- Readers68
- 68
Article Description
Graded-index (GRIN) lenses serve as a key component for miniature endoscopes because of their small diameters and ease of assembly. However, the nonaplanatic nature of GRIN lenses causes inherent spatial aberrations that lower image resolution and sharpness. Here we present the diagnosis of the aberrations in GRIN probes and the use of adaptive optics to compensate for the wavefront errors in the endoscope. Two different operation schemes based on preset and in situ measurements are demonstrated, both resulting in a substantial reduction of the wave-front error from 0.42 to <0.1 μm. © 2011 Optical Society of America.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=82955202794&origin=inward; http://dx.doi.org/10.1364/ol.36.004608; http://www.ncbi.nlm.nih.gov/pubmed/22139258; https://opg.optica.org/abstract.cfm?URI=ol-36-23-4608; https://www.osapublishing.org/abstract.cfm?URI=ol-36-23-4608; https://www.osapublishing.org/viewmedia.cfm?URI=ol-36-23-4608&seq=0; https://dx.doi.org/10.1364/ol.36.004608; https://opg.optica.org/ol/abstract.cfm?uri=ol-36-23-4608; http://www.opticsinfobase.org/abstract.cfm?URI=ol-36-23-4608; https://opg.optica.org/abstract.cfm?uri=ol-36-23-4608; https://opg.optica.org/viewmedia.cfm?uri=ol-36-23-4608&seq=0&html=true; https://opg.optica.org/viewmedia.cfm?uri=ol-36-23-4608&seq=0; https://www.osapublishing.org/ol/abstract.cfm?uri=ol-36-23-4608
Optica Publishing Group
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know