Simultaneous phase and amplitude aberration sensing with a liquid-crystal vector-Zernike phase mask
Optics Letters, ISSN: 1539-4794, Vol: 44, Issue: 1, Page: 17-20
2019
- 30Citations
- 20Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations30
- Citation Indexes30
- 30
- CrossRef8
- Captures20
- Readers20
- 20
Article Description
We present an enhanced version of the Zernike wavefront sensor (WFS), which simultaneously measures phase and amplitude aberrations. The “vector-Zernike” WFS consists of a patterned liquid-crystal mask, which imposes a π∕2 phase on the point spread function core through the achromatic geometric phase acting with the opposite sign on opposite circular polarizations. After splitting circular polarization, the ensuing pupil intensity images are used to reconstruct the phase and the amplitude of the incoming wavefront. We demonstrate reconstruction of the complex wavefront with monochromatic lab measurements and show in simulation the high accuracy and sensitivity over a bandwidth up to 100%.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85059237240&origin=inward; http://dx.doi.org/10.1364/ol.44.000017; http://www.ncbi.nlm.nih.gov/pubmed/30645534; https://opg.optica.org/abstract.cfm?URI=ol-44-1-17; https://dx.doi.org/10.1364/ol.44.000017; https://opg.optica.org/ol/abstract.cfm?uri=ol-44-1-17