Technique for enhancing the accuracy of the Rayleigh-Sommerfeld convolutional diffraction through the utilization of independent spatial sampling
Optics Letters, ISSN: 1539-4794, Vol: 49, Issue: 5, Page: 1385-1388
2024
- 1Citations
- 1Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations1
- Citation Indexes1
- CrossRef1
- Captures1
- Readers1
Letter Description
The Rayleigh-Sommerfeld diffraction integral (RSD) is a rigorous solution that precisely satisfies both Maxwell's equations and Helmholtz's equations. It seamlessly integrates Huygens' principle, providing an accurate description of the coherent light propagation within the entire diffraction field. Therefore, the rapid and precise computation of the RSD is crucial for light transport simulation and optical technology applications based on it. However, the current FFT-based Rayleigh-Sommerfeld integral convolution algorithm (CRSD) exhibits poor performance in the near field, thereby limiting its applicability and impeding further development across various fields. The present study proposes, to our knowledge, a novel approach to enhance the accuracy of the Rayleigh-Sommerfeld convolution algorithm by employing independent sampling techniques in both spatial and frequency domains. The crux of this methodology involves segregating the spatial and frequency domains, followed by autonomous sampling within each domain. The proposed method significantly enhances the accuracy of RSD during the short distance while ensuring computational efficiency.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85186329719&origin=inward; http://dx.doi.org/10.1364/ol.509688; http://www.ncbi.nlm.nih.gov/pubmed/38427019; https://opg.optica.org/abstract.cfm?URI=ol-49-5-1385; https://dx.doi.org/10.1364/ol.509688; https://opg.optica.org/ol/abstract.cfm?uri=ol-49-5-1385