Low operating voltage monolithic stacked perovskite photodetectors for imaging applications
Optical Materials Express, ISSN: 2159-3930, Vol: 11, Issue: 4, Page: 1004-1013
2021
- 3Citations
- 5Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The monolithic stacked design is expected to solve the challenges of wiring difficulties, complex fabrication processes, and low resolution. However, a photodetector array with low operating voltage that is suitable for imaging applications has not been proposed. Here, a perovskite photodetector array with a monolithic stacked structure is proposed. The CHNHPbI photodetector has a low power consumption off-state (0 V) and on-state (2 V) voltage, and the highest responsivity and specific detectivity of 0.39 A/W and 4.53×1012 Jones at 775 nm, respectively. The rise time and decay time are 111 µs and 250 µs respectively. In addition, the imaging application shows high contrast, which provides a simple and effective way to prepare high performance perovskite imaging devices.
Bibliographic Details
Optica Publishing Group
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know