Light sheet microscope scanning of biointegrated microlasers for localized refractive index sensing
Photonics Research, ISSN: 2327-9125, Vol: 12, Issue: 8, Page: 1673-1680
2024
- 4Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures4
- Readers4
Article Description
Whispering gallery mode (WGM) microlasers are highly sensitive to localized refractive index changes allowing to link their emission spectrum to various chemical, mechanical, or physical stimuli. Microlasers recently found applications in biological studies within single cells, in three-dimensional samples such as multicellular spheroids, or in vivo. However, detailed studies of biological samples also need to account for the structural heterogeneity of tissues and live animals, therefore requiring a combination of high-resolution microscopy and laser spectroscopy. Here, we design and construct a light sheet fluorescence microscope with a coupled spectrometer for use in microlaser studies for combined high-resolution, high-speed imaging and WGM spectral analysis. The light sheet illumination profile and the decoupled geometry of excitation and emission hereby directly affect the lasing and sensing properties, mainly through geometric constraints and by light coupling effects. We demonstrate the basic working principle of microlaser spectroscopy under light sheet excitation and measure the absolute refractive index within agarose and in zebrafish tail muscle tissue. We further analyze the light coupling conditions that lead to the occurrence of two separate oscillation planes. These so-called cross modes can be scanned around the entire microlaser surface, which allows to estimate a surface-averaged refractive index profile of the microlaser environment.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85201148184&origin=inward; http://dx.doi.org/10.1364/prj.522018; https://opg.optica.org/abstract.cfm?URI=prj-12-8-1673; https://dx.doi.org/10.1364/prj.522018; https://opg.optica.org/prj/fulltext.cfm?uri=prj-12-8-1673&id=553897; http://sciencechina.cn/gw.jsp?action=cited_outline.jsp&type=1&id=7824685&internal_id=7824685&from=elsevier
Optica Publishing Group
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know