Development of a screening tool for sleep disordered breathing in children using the phone oximeter

PLoS ONE, ISSN: 1932-6203, Vol: 9, Issue: 11, Page: e112959
2014
  • 93
    Citations
  • 0
    Usage
  • 185
    Captures
  • 0
    Mentions
  • 5
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

  • Citations
    93
  • Captures
    185
  • Social Media
    5
    • Shares, Likes & Comments
      5
      • Facebook
        5

Article Description

Background: Sleep disordered breathing (SDB) can lead to daytime sleepiness, growth failure and developmental delay in children. Polysomnography (PSG), the gold standard to diagnose SDB, is a highly resource-intensive test, confined to the sleep laboratory. Copyright: Aim: To combine the blood oxygen saturation (SpO) characterization and cardiac modulation, quantified by pulse rate variability (PRV), to identify children with SDB using the Phone Oximeter, a device integrating a pulse oximeter with a smartphone. Methods: Following ethics approval and informed consent, 160 children referred to British Columbia Children's Hospital for PSG was attached to the Phone Oximeter to record overnight pulse oximetry (SpO and photoplethysmogram (PPG)) overnight PSG were recruited. A second pulse oximeter sensor applied to the finger adjacent to the one used for standard alongside the PSG. Results: We studied 146 children through the analysis of the SpO pattern, and PRV as an estimate of heart rate variability calculated from the PPG. SpO variability and SpO spectral power at low frequency, was significantly higher in children with SDB due to the modulation provoked by airway obstruction during sleep (p-value <0:01). PRV analysis reflected a significant augmentation of sympathetic activity provoked by intermittent hypoxia in SDB children. A linear classifier was trained with the most discriminating features to identify children with SDB. The classifier was validated with internal and external cross-validation, providing a high negative predictive value (92.6%) and a good balance between sensitivity (88.4%) and specificity (83.6%). Combining SpO and PRV analysis improved the classification performance, providing an area under the receiver operating characteristic curve of 88%, beyond the 82% achieved using SpO analysis alone. Conclusions: These results demonstrate that the implementation of this algorithm in the Phone Oximeter will provide an improved portable, at-home screening tool, with the capability of monitoring patients over multiple nights.

Bibliographic Details

Ainara Garde; Parastoo Dehkordi; Walter Karlen; David Wensley; J. Mark Ansermino; Guy A. Dumont; Eric Murillo-Rodriguez

Public Library of Science (PLoS)

Biochemistry, Genetics and Molecular Biology; Agricultural and Biological Sciences; Multidisciplinary

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know