Simple ultraviolet microscope using off-the-shelf components for point-of-care diagnostics
PLoS ONE, ISSN: 1932-6203, Vol: 14, Issue: 4, Page: e0214090
2019
- 6Citations
- 20Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations6
- Citation Indexes6
- CrossRef1
- Captures20
- Readers20
- 20
Article Description
At the primary care setting, where there are often no or minimal laboratories, examinations often consist of self-testing and rapid diagnostics. Because of this, medical devices must be simple, robust, and easy to operate. To address these concerns, an alternate fluorescence microscope design uses ultraviolet (UV) excitation, since fluorescent dyes that are excitable in the visible region are also excitable by UV. This may allow for the removal of typical excitation, emission, and dichroic filters as optical components absorb UV wavelengths and UV is not detected by silicon based detectors. Additionally, UV has a very low penetration into samples, which may allow for controlling the depth of excitation, and thus the imaging volume. Based on these ideas, we developed a simple fluorescence microscope built completely from off-the-shelf components that uses UV to image fluorescently stained samples. The simple opto-mechanical design of the system may allow it to be more compact and easy to use, as well as decrease the overall cost of the diagnostic device. For biological validation, we imaged whole blood stained with acridine orange and performed a two-part white blood cell differential count.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85064163931&origin=inward; http://dx.doi.org/10.1371/journal.pone.0214090; http://www.ncbi.nlm.nih.gov/pubmed/30970020; https://dx.plos.org/10.1371/journal.pone.0214090; https://dx.doi.org/10.1371/journal.pone.0214090; https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0214090