Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
Polimery/Polymers, ISSN: 0032-2725, Vol: 66, Issue: 11-12, Page: 589-601
2021
- 1Citations
- 13Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Three different carbon paste (CP), silk-screen (SP) and poly (vinyl chloride) (PVC) modified electrodes were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCl (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.010-6 to 1.010-2 mol/L AV-MOXH at 25°C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca+, etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2-6 for ISPE electrodes and IPVC electrodes and 3-7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the "HPLC official method" in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.
Bibliographic Details
LUKASIEWICZ Research Network - Industrial Chemistry Research Institute
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know