Influence of sizes of abutments and fixation screws on dental implant system: a non-linear finite element analysis
Biomedizinische Technik, ISSN: 0013-5585, Vol: 62, Issue: 4, Page: 357-364
2017
- 11Citations
- 28Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The purpose of this study is to discuss the influence of sizes of abutments and fixation screws on immediately loaded dental implants in mandibular bones using nonlinear finite element methods. Abutments with three unilateral wall thicknesses and fixation screws with three diameters are analyzed to compare the stresses and deformations under a vertical or oblique force of 130 N. The nonlinearity due to friction contacts between the fixation screw, the abutment, the implant, and the bone is taken into account. The results showed that improper sizes of abutments and fixation screws would increase the stress and deformation of the dental implant system. If possible, the diameter of fixation screw should not be smaller than Φ1.0 mm, the diameter between Φ1.0 mm and Φ1.2 mm is acceptable. The fixation screw diameter preferably exceeds Φ1.4 mm. The unilateral wall thickness >0.5 mm is optimal selection for abutments.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85027404956&origin=inward; http://dx.doi.org/10.1515/bmt-2015-0074; http://www.ncbi.nlm.nih.gov/pubmed/27514072; https://www.degruyter.com/document/doi/10.1515/bmt-2015-0074/html; http://www.degruyter.com/view/j/bmte.2017.62.issue-4/bmt-2015-0074/bmt-2015-0074.xml; https://www.degruyter.com/view/j/bmte.2017.62.issue-4/bmt-2015-0074/bmt-2015-0074.xml
Walter de Gruyter GmbH
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know