Deformation behaviour of strontium titanate between room temperature and 1800 K under ambient pressure
International Journal of Materials Research, ISSN: 1862-5282, Vol: 95, Issue: 6, Page: 433-446
2004
- 3Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures3
- Readers3
Article Description
SrTiO3 was plastically deformed in compression along different crystal axes between room temperature and 1800 K. Data obtained from deformation experiments as well as from light optical and electron optical studies are presented. Irrespective of the compression axis orientation, the material exhibits a strongly pronounced ductile-to-brittle-to-ductile behaviour. For the <100> compression axis the slip system <110>{110} is active both at low and high temperatures. For compression axes other than <100> the <110>{110} system is active only at low temperatures whereas at high temperatures the <100>{110} system dominates. This behaviour is discussed in terms of dislocation core structures.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know