Dynamic contour tonometry versus Goldmann applanation tonometry: Challenging the gold standard
Expert Review of Ophthalmology, ISSN: 1746-9902, Vol: 5, Issue: 6, Page: 743-749
2010
- 7Citations
- 9Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Review Description
The accurate measurement of intraocular pressure (IOP) is fundamental to almost any ophthalmic examination. Dynamic contour tonometry (DCT) was introduced 5 years ago as an entirely novel contact tonometry principle designed to measure IOP largely independently of corneal properties. Since then, many studies have compared the performance of this tonometer to the Goldmann applanation tonometer (GAT) and other tonometers in healthy eyes, as well as eyes with glaucoma or corneal diseases, and after corneal surgery. There is now strong evidence that DCT measures IOP very accurately, with very low inter- and intraobserver variability. This article summarizes the findings of these studies and analyzes the role of DCT in challenging GAT as the gold-standard tonometer for IOP measurements. © 2010 Expert Reviews Ltd.