A simple paper-based colorimetric device for rapid and sensitive urinary oxalate determinations
Analytical Sciences, ISSN: 1348-2246, Vol: 34, Issue: 1, Page: 103-108
2018
- 20Citations
- 15Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations20
- Citation Indexes20
- 20
- CrossRef13
- Captures15
- Readers15
- 15
Article Description
In this work, a simple and inexpensive paper-based colorimetric device (cPAD) was developed for oxalate measurements. The colorimetric assay is based on the formation of formazan via the reduction of 3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide (MTT) by oxalate decarboxylase and formate dehydrogenase on the paper device. After the sample was spotted on the device, MTT changed color from yellow to purple, and the purple color intensity correlated with the oxalate concentration. The quantitative detection of oxalate ranged from 10 - 1000 μM, with a linear equation, y = 0.0086x + 34.978, and a correlation coefficient (R ) = 0.9994. The detection limit was 10 μM by the naked eye. The recoveries of oxalate spiked in artificial urine samples evaluated by our cPADs were in the range of 81 - 92%. This simple cPAD for rapid and sensitive oxalate determination should be useful for diagnostic urinary oxalate measurements for point-of-care monitoring.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85041843886&origin=inward; http://dx.doi.org/10.2116/analsci.34.103; http://www.ncbi.nlm.nih.gov/pubmed/29321449; https://link.springer.com/10.2116/analsci.34.103; https://dx.doi.org/10.2116/analsci.34.103; https://link.springer.com/article/10.2116/analsci.34.103; https://www.jstage.jst.go.jp/article/analsci/34/1/34_103/_article/-char/en/; https://www.jstage.jst.go.jp/article/analsci/34/1/34_103/_article/-char/ja/
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know