Highly sensitive paper-based analytical devices with the introduction of a large-volume sample via continuous flow
Analytical Sciences, ISSN: 1348-2246, Vol: 34, Issue: 1, Page: 65-70
2018
- 18Citations
- 17Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations18
- Citation Indexes18
- 18
- CrossRef13
- Captures17
- Readers17
- 17
Article Description
The implementation of continuous flow in paper-based analytical devices (PADs) was challenging because of the largevolume introduction that was created; but this allowed for the development of novel types of PADs for preconcentration, separation, and sensitive detection. In this study, pump-free continuous flow was applied to a distance-based PAD for the determination of iron ions. Continuous flow enabled the introduction of a volume that exceeded what was necessary to fill the hydrophilic channel of a PAD. Thus, this continuous-flow method significantly improved both the limits of detection (LOD) and the limits of quantification (LOQ) for a distance-based PAD by increasing the sample volume that could be introduced into the PAD. The values for LOD and LOQ were 20 and 26 ppb, respectively, which were more than 150-times lower than that obtained using a small sample volume (50 μL), and were comparable to those of inductively coupled plasma-atomic emission spectrometry. The continuous-flow technique was applicable to the determination of iron ions at levels of several tens of ppb in natural water without preconcentration.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85041806576&origin=inward; http://dx.doi.org/10.2116/analsci.34.65; http://www.ncbi.nlm.nih.gov/pubmed/29321460; https://link.springer.com/10.2116/analsci.34.65; https://dx.doi.org/10.2116/analsci.34.65; https://link.springer.com/article/10.2116/analsci.34.65; https://www.jstage.jst.go.jp/article/analsci/34/1/34_65/_article/-char/en/; https://www.jstage.jst.go.jp/article/analsci/34/1/34_65/_article/-char/ja/
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know