PlumX Metrics
Embed PlumX Metrics

A One Step Strategy Based on Hollow Gold Nanoparticles to Detect C-Reactive Protein with High Sensitivity (Hs-CRP) in Serum for Monitoring Cardiovascular Disease

International Journal of Nanomedicine, ISSN: 1178-2013, Vol: 19, Page: 845-858
2024
  • 1
    Citations
  • 0
    Usage
  • 5
    Captures
  • 0
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Article Description

Purpose: Rapid detection and diagnosis of diseases facilitate timely and effective treatment of cardiovascular diseases (CVD). The establishment of a one-step rapid detection method provides a new method for the initial screening and disease risk assessment of patients with cardiovascular diseases in primary medical units. Methods: Hollow gold nanoparticles (HGNPs) were synthesized using a cobalt template method followed by use as signal amplification probes for ultra-sensitive quantitative detection of serum C-reactive protein (CRP). To induce the localized surface plasmon resonance (LSPR) and improve protein labeling efficiency, we developed a sensitive detection mode by coating polyvinyl-pyrrolidone (PVP-K30) on the HGNPs, resulting in a significant improvement in detection performance. Results: Compared to traditional colloidal GNP-based LFTA, PVP-coated HGNPs exhibit a lower visual detection limit of 1 ng/mL, which a 25-fold decrement compare to using GNPs as the antibody-labeled probe, and the detection limit could be reduced to 0.14 ng/ mL under the quantitative instrument. Conclusion: The one-step method based on HGNP immunochromatographic strips modified with PVP established in this study can be used for the detection of CRP and hs-CRP in biological samples. The performance of the immunochromatographic technique designed in this study was evaluated from the perspective of synthetic markers, and the application conditions of this strip were screened, verifying its high specificity, indicating that it has high sensitivity and strong detection limit compared to colloidal gold. The sensitivity of the hollow gold immunochromatographic test strip in this article has been increased by about 25 times, providing a new method for rapid detection of CVD in clinical diagnosis.

Bibliographic Details

Luo, Changyou; Zhang, Ruiqing; Liu, Ji; He, Xingyue; Li, Shengzhou; Ran, Chuanjiang; Ma, Songbo; Shen, Yan

Informa UK Limited

Biochemistry, Genetics and Molecular Biology; Chemical Engineering; Materials Science; Pharmacology, Toxicology and Pharmaceutics; Chemistry

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know