Numerical Simulation of the Piezo-Optical Strain Sensor Gauge Factor
Optoelectronics, Instrumentation and Data Processing, ISSN: 1934-7944, Vol: 55, Issue: 3, Page: 296-302
2019
- 1Citations
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations1
- Citation Indexes1
- CrossRef1
Article Description
The dependence of the piezo-optical strain sensor gauge factor on the geometric parameters of the photoelastic element is obtained by accurate numerical simulations. It is shown that the piezo-optical gauge sensitivity to the applied force is more dependent on the photoelastic element shape than the sensitivity to deformation. A comparative analysis of the gauge factors and other parameters of strain-resistive, piezoelectric, fiber-optic, and piezo-optical strain gauges was carried out. Strain-resistive and fiber-optic sensor gauge factors are three orders of magnitude lower than those of piezo-optical sensors. Correctly calculated piezoelectric sensor gauge factors are also two-three orders of magnitude inferior to those of piezo-optical sensors. A comparison of the basic properties and parameters of modern commerical strain gauges based on different physical principles is presented.
Bibliographic Details
Allerton Press
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know