The systemic effect of 830-nm LED phototherapy on the wound healing of burn injuries: A controlled study in mouse and rat models
Journal of Cosmetic and Laser Therapy, ISSN: 1476-4172, Vol: 14, Issue: 2, Page: 107-110
2012
- 23Citations
- 28Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations23
- Citation Indexes23
- 23
- CrossRef11
- Captures28
- Readers28
- 28
Article Description
Background: The present controlled study assessed the systemic effect of 830-nm LED phototherapy in rodent models. Materials and methods: Two HR-1 hairless mice and 3 HWY/Slc hairless rats were divided into two groups: the treatment group (Tx Group, one mouse, two rats) and the control group (Con Group, one mouse, one rat). All animals received an identical 12 mm × 12 mm control burn over three sites on the dorsum with a fractional ablative CO2 laser. Wounds were protected with a film-type dressing. The abdomen of the Tx Group subjects was irradiated with an 830-nm LED array immediately post CO2 treatment and then at 1, 5 and 6 days post laser irradiation. Wound healing was assessed macroscopically from the clinical photography. Results: At the 2-day post-laser assessment, the healing process in the wounds in the Tx Group was already apparent compared with the Con Group. At the final evaluation (post-burn day 7), no site on the Con Group (six wounds) showed 100% healing, recovery was over 70% in four and lower than 50% in two sites. Of the nine Tx Group sites, 100% recovery was seen in three sites, over 70% in five sites and one wound was exacerbated through trauma. Conclusions: LED phototherapy on the abdomen produced faster wound healing of the uniform burn wounds than in animals with the same burn wounds that did not receive LED phototherapy, strongly suggesting the systemic effect of phototherapy. © 2012 Informa UK, Ltd.
Bibliographic Details
Informa UK Limited
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know