Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model
Journal of Neurosurgery, ISSN: 0022-3085, Vol: 95, Issue: 2 SUPPL., Page: 215-220
2001
- 47Citations
- 25Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations47
- Citation Indexes46
- 46
- CrossRef10
- Clinical Citations1
- PubMed Guidelines1
- Captures25
- Readers25
- 25
Article Description
Object. Polymethylmethacrylate (PMMA) has long been used in the stabilization and reconstruction of traumatic and pathological fractures of the spine. Recently, hydroxyapatite (HA), an osteoconductive, biocompatible cement, has been used as an alternative to PMMA. In this study the authors compare the stabilizing effects of the HA product, BoneSource, with PMMA in an experimental compression fracture of L-1. Methods. Twenty T9-L3 cadaveric spine specimens were mounted individually on a testing frame. Light-emitting diodes were placed on the neural arches as well as the base. Motion was tracked by two video cameras in response to applied loads of 0 to 6 Mm. The weight-drop technique was used to induce a reproducible compression fracture of T-11 after partially coring out the vertebra. Load testing was performed on the intact spine, postfracture, after unilateral transpedicular vertebroplasty with 7 to 10 ml of PMMA or HA, and after flexion-extension fatiguing to 5000 cycles at ±3 Nm. No significant difference between the HA- and PMMA cemented-fixated spines was demonstrated in flexion, extension, left lateral bending, or right and left axial rotation. The only difference between the two cements was encountered before and after fatiguing in right lateral bending (p ≤ 0.05). Conclusions. The results of this study suggest that the same angular rigidity can be achieved using either HA or PMMA. This is of particular interest because HA is osteoconductive, undergoes remodeling, and is not exothermic.
Bibliographic Details
Journal of Neurosurgery Publishing Group (JNSPG)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know