Methods of increasing spectral resolution of imaging spectrometers built on the basis of multi–channel radiation detectors
Light and Engineering, ISSN: 2541-9935, Vol: 28, Issue: 6, Page: 95-014
2020
- 1Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures1
- Readers1
Article Description
The article proposes the methods of object shooting by means of a spectrometer based on a multi-channel radiation detector and further processing of its results allowing spectral resolution of such spectrometers significantly to increase with the same original spatial resolution. The mathematical model of the shooting process is provided. It is determined that restoration of spectral radiance of objects based on the shooting data using the proposed method is a mathematically incorrect inverse task. The Greville method, the method of wavelet trans-formation, the Tikhonov regularisation method, and the Godunov method were considered as methods for its solution. The results of computational modelling of the considered methods are shown and it is found that restoration of spectral radiance of objects based on the shooting data using the considered methods is possible and relative error of restoration is at a fraction of per cent scale. It is determined that the wavelet transformation method is an optimal method of solution of the incorrect spectral radiance restoration task. It is also shown that the proposed method of imaging spectrometry is applicable both when using matrix radiation detectors with in-creased number of narrow-band filters and when using widely spread standard three-channel matrix RGB detectors of radiation.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85101875413&origin=inward; http://dx.doi.org/10.33383/2019-098; https://l-e-journal.com/en/journals/light-engineering-28-6/methods-of-increasing-spectral-resolution-of-imaging-spectrometers-built-on-the-basis-of-multi-chann/; https://dx.doi.org/10.33383/2019-098
Redakcia Zhurnala Svetotekhnika LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know