PlumX Metrics
Embed PlumX Metrics

Combined Shear Wave Elastography and EU TIRADS in Differentiating Malignant and Benign Thyroid Nodules

Cancers, ISSN: 2072-6694, Vol: 14, Issue: 22
2022
  • 14
    Citations
  • 0
    Usage
  • 10
    Captures
  • 1
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent News

Hong Kong Polytechnic University Researchers Highlight Research in Thyroid Nodules (Combined Shear Wave Elastography and EU TIRADS in Differentiating Malignant and Benign Thyroid Nodules)

2022 DEC 13 (NewsRx) -- By a News Reporter-Staff News Editor at Disease Prevention Daily -- Investigators publish new report on thyroid nodules. According to

Article Description

Although multimodal ultrasound approaches have been suggested to potentially improve the diagnosis of thyroid cancer; the diagnostic utility of the combination of SWE and malignancy-risk stratification systems remains vague due to the lack of standardized criteria. The purpose of the study was to assess the diagnostic value of the combination of grey scale ultrasound assessment using EU TIRADS and shear wave elastography. 121 patients (126 nodules–81 benign; 45 malignant) underwent grey scale ultrasound and SWE imaging of nodules between 0.5 cm and 5 cm prior to biopsy and/or surgery. Nodules were analyzed based on size stratifications: <1 cm (n = 43); 1–2 cm (n = 52) and >2 cm (n = 31) and equivocal cytology status (n = 52), and diagnostic performance assessments were conducted. The combination of EU TIRADS with SWE using the SD parameter; maintained a high sensitivity and significantly improved the specificity of sole EU TIRADS for nodules 1–2 cm (SEN: 72.2% vs. 88.9%, p > 0.05; SPEC: 76.5% vs. 55.9%, p < 0.01) and >2 cm (SEN: 71.4% vs. 85.7%, p > 0.05; SPEC: 95.8% vs. 62.5%, p < 0.01). For cytologically-equivocal nodules; the combination with the SWE minimum parameter resulted in a significant reduction in sensitivity with increased specificity (SEN: 60% vs. 80%; SPEC: 83.4% vs. 37.8%; all p < 0.05). SWE in combination with EU TIRADS is diagnostically efficient in discriminating nodules > 1 cm but is not ideal for discriminating cytologically-equivocal nodules.

Bibliographic Details

Chambara, Nonhlanhla; Lo, Xina; Chow, Tom Chi Man; Lai, Carol Man Sze; Liu, Shirley Yuk Wah; Ying, Michael

MDPI AG

Medicine; Biochemistry, Genetics and Molecular Biology

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know