PlumX Metrics
Embed PlumX Metrics

A Small Scale Optically Pumped Fetal Magnetocardiography System

Journal of Clinical Medicine, ISSN: 2077-0383, Vol: 12, Issue: 10
2023
  • 2
    Citations
  • 0
    Usage
  • 6
    Captures
  • 2
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent Blog

JCM, Vol. 12, Pages 3380: A Small Scale Optically Pumped Fetal Magnetocardiograhpy System

JCM, Vol. 12, Pages 3380: A Small Scale Optically Pumped Fetal Magnetocardiograhpy System Journal of Clinical Medicine doi: 10.3390/jcm12103380 Authors: David Wurm Peter Ewert Peter

Most Recent News

Studies Conducted at Technical University Munich (TU Munich) on Clinical Medicine Recently Published (A Small Scale Optically Pumped Fetal Magnetocardiography System)

2023 MAY 30 (NewsRx) -- By a News Reporter-Staff News Editor at NewsRx Medical Devices Daily -- Investigators publish new report on clinical medicine. According

Article Description

Introduction: Fetal magnetocardiography (fMCG) is considered the best technique for diagnosis of fetal arrhythmia. It is superior to more widely used methods such as fetal, fetal electrocardiography, and cardiotocography for evaluation of fetal rhythm. The combination of fMCG and fetal echocardiography can provide a more comprehensive evaluation of fetal cardiac rhythm and function than is currently possible. In this study, we demonstrate a practical fMCG system based on optically pumped magnetometers (OPMs). Methods: Seven pregnant women with uncomplicated pregnancies underwent fMCG at 26–36 weeks’ gestation. The recordings were made using an OPM-based fMCG system and a person-sized magnetic shield. The shield is much smaller than a shielded room and provides easy access with a large opening that allows the pregnant woman to lie comfortably in a prone position. Results: The data show no significant loss of quality compared to data acquired in a shielded room. Measurements of standard cardiac time intervals yielded the following results: PR = 104 ± 6 ms, QRS = 52.6 ± 1.5 ms, and QTc = 387 ± 19 ms. These results are compatible with those from prior studies performed using superconducting quantum interference device (SQUID) fMCG systems. Conclusions: To our knowledge, this is the first European fMCG device with OPM technology commissioned for basic research in a pediatric cardiology unit. We demonstrated a patient-friendly, comfortable, and open fMCG system. The data yielded consistent cardiac intervals, measured from time-averaged waveforms, compatible with published SQUID and OPM data. This is an important step toward making the method widely accessible.

Bibliographic Details

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know