Heart Rate Recovery Index and Improved Diastolic Dyssynchrony in Fusion Pacing Cardiac Resynchronization Therapy
Journal of Clinical Medicine, ISSN: 2077-0383, Vol: 13, Issue: 21
2024
- 2Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
- Mentions1
- News Mentions1
- 1
Most Recent News
Researcher from Doctoral School Publishes Findings in Cardiac Resynchronization Therapy (Heart Rate Recovery Index and Improved Diastolic Dyssynchrony in Fusion Pacing Cardiac Resynchronization Therapy)
2024 NOV 12 (NewsRx) -- By a News Reporter-Staff News Editor at NewsRx Cardiovascular Daily -- Research findings on cardiac resynchronization therapy are discussed in
Article Description
Background: Restoring electrical synchrony with cardiac resynchronization therapy (CRT) reverses the heart failure phenotype developed by left-ventricular (LV) dyssynchrony. This study aimed to identify new predictors of response to LV-only fusion pacing CRT. Methods: A select group of patients with CRT-P indications received a right atrium (RA)/LV DDD pacing system. LV dyssynchrony was assessed via offline TDI timing focusing on the temporal difference between peak septal (E″T) and lateral wall (A“T) motion. CRT effectiveness was evaluated at each follow-up, involving the heart rate recovery index (HRRI) parameter (acceleration/deceleration time) derived from exercise testing along with the echocardiographic parameters. Patients were classified into super-responders (SR), responders (R), and non-responders (NR). Results: Baseline initial characteristics: 62 patients (35 male) aged 62 ± 11 y.o. with non-ischemic dilated cardiomyopathy (DCM). Ejection fraction (EF) 27 ± 5.2%; QRS 164 ± 18 ms; 29% had type III diastolic dysfunction (DD), 63% type II DD, and 8% type I DD. Average follow-up was 45 ± 19 months: 34% of patients were SR, 61% R, and 5% NR. The E″T decreased from 90 ± 20 ms to 25 ± 10 ms in SR, with a shorter deceleration time (DT) during exercise test compared to NR (109 ± 68 ms vs. 330 ± 30 ms; p < 0.0001). The responders present a higher HRRI (2.87 ± 1.47 vs. 0.98 ± 0.08; p = 0.03) compared to NR and a significantly decrease in E“T and A“T from 76 ± 13 ms to 51 ± 11 ms (p < 0.0001). Prolonged DT was associated with an accentuated LV dyssynchrony and nonoptimal response to CRT. Conclusions: The study identified new parameters for assessing responsiveness to LV-only fusion pacing CRT, which could improve candidate selection and CRT implementation.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know