PlumX Metrics
Embed PlumX Metrics

Efficacy of Intermittent and Continuous Subglottic Secretion Drainage in Preventing the Risk of Ventilator-Associated Pneumonia: A Meta-Analysis of Randomized Control Trials

Medicina (Lithuania), ISSN: 1648-9144, Vol: 59, Issue: 2
2023
  • 5
    Citations
  • 0
    Usage
  • 40
    Captures
  • 2
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent Blog

Medicina, Vol. 59, Pages 283: Efficacy of Intermittent and Continuous Subglottic Secretion Drainage in Preventing the Risk of Ventilator-Associated Pneumonia: A Meta-Analysis of Randomized Control Trials

Medicina, Vol. 59, Pages 283: Efficacy of Intermittent and Continuous Subglottic Secretion Drainage in Preventing the Risk of Ventilator-Associated Pneumonia: A Meta-Analysis of Randomized Control

Most Recent News

Researcher at University of Airlangga Has Published New Study Findings on Ventilator-Associated Pneumonia (Efficacy of Intermittent and Continuous Subglottic Secretion Drainage in Preventing the Risk of Ventilator-Associated Pneumonia: A ...)

2023 FEB 16 (NewsRx) -- By a News Reporter-Staff News Editor at Disease Prevention Daily -- A new study on ventilator-associated pneumonia is now available.

Article Description

Ventilator-associated pneumonia (VAP) is hospital-acquired pneumonia that develops 48 h or longer following mechanical ventilation. However, cuff pressure fluctuates significantly due to patient or tube movement, which might result in microaspiration. Subglottic secretion drainage (SSD) has been suggested as a method for VAP prevention bundles. This systematic review and meta-analysis aims to investigate the efficacy and safety of subglottic SSD in preventing VAP. The secondary outcomes of this study are to investigate the intensive care unit (ICU) stay length and mortality rate regarding VAP. This study followed the Preferred Reporting Item for Systematic Review and Meta-Analysis guidelines. A thorough search of PubMed, Embase, and the Web of Science was conducted between June and August 2022. The study analysis used the Mantel–Haenszel method, and the quality of the included study was assessed using the Cochrane Risk of Bias 2. Eighteen randomized controlled trials with a total of 2537 intubated patients were included. It was found that SSD was associated with a lower risk of VAP (RR 1.44; 95% CI; 1.20–1.73; p < 0.0001). The subgroup analysis (utilizing intermittent and continuous methods) found no statistically significant difference between the two groups (p = 0.28). The secondary endpoints showed that there was no significant difference in mortality (RR 1.02; 95% CI; 0.87–1.20; p = 0.83), but there were substantial differences in ICU stays (mean difference, 3.42 days; 95% CI; 2.07–4.76; p < 0.00001) in favor of the SSD group. This was based on a very low certainty of evidence due to concerns linked to the risk of bias and inconsistency. The use of SSD was associated with a reduction in VAP incidence and ICU stay length, but there was no significant difference in the mortality rate.

Bibliographic Details

Dewi, Yulis Setiya; Arifin, Hidayat; Pradipta, Rifky Octavia; Qona'ah, Arina; Rosita, Rosita; Giatin, Cindy Nanda; Dawod Kamel Gauda, Amel

MDPI AG

Medicine

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know