Imaging-Based Drug Penetration Profiling in an Excised Sheep Cornea Model
Pharmaceutics, ISSN: 1999-4923, Vol: 16, Issue: 9
2024
- 2Captures
- 2Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
- Mentions2
- News Mentions2
- News2
Most Recent News
Imaging-Based Drug Penetration Profiling in an Excised Sheep Cornea Model
Abstract Formulations designed to address ocular conditions and diseases are predominantly administered topically. While in vitro test systems have been developed to assess corneal permeation
Article Description
Formulations designed to address ocular conditions and diseases are predominantly administered topically. While in vitro test systems have been developed to assess corneal permeation under extended contact conditions, methods focusing on determining the penetration depth and kinetics of a substance within the cornea itself rather than through it, are scarce. This study introduces a method for time-dependent penetration depth analysis (10 and 60 min) by means of a semiquantitative imaging method in comparison with a quantitative corneal depth-cut technique, employing fluorescein sodium at concentrations of 0.2 and 0.4 mg/mL as a small molecule model substance and sheep cornea as a human surrogate. Excised tissues exhibited sustained viability in modified artificial aqueous humor and maintained thickness (746 ± 43 µm) and integrity (electrical resistance 488 ± 218 Ω∙cm) under the experimental conditions. Both methods effectively demonstrated the expected concentration- and time-dependent depth of penetration of fluorescein sodium, displaying a significantly strong correlation. The traceability of the kinetic processes was validated with polysorbate 80, which acted as a penetration enhancer. Furthermore, the imaging-based method enabled detecting the retention of larger structures, such as hyaluronic acid and nanoemulsions from the commercial eyedrop formulation NEOVIS TOTAL multi, inside the lacrimal layer.