PlumX Metrics
Embed PlumX Metrics

Effect of different head hole position on the rotational resistance and stability of orthodontic miniscrews: A three-dimensional finite element study

Sensors, ISSN: 1424-8220, Vol: 21, Issue: 11
2021
  • 2
    Citations
  • 0
    Usage
  • 9
    Captures
  • 1
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

  • Citations
    2
  • Captures
    9
  • Mentions
    1
    • Blog Mentions
      1
      • Blog
        1

Most Recent Blog

Sensors, Vol. 21, Pages 3798: Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study

Sensors, Vol. 21, Pages 3798: Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study

Article Description

The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole position from the long axis. Two miniscrew models were developed, one with the head hole at the long axis and the other with an eccentric hole position. One degree of counter-clockwise rotation was applied to both groups, and the maximum Von-Mises stress and moment was measured under various wire insertion angles from −60° to +60°. All Von-Mises stress and moments increased with an increase in rotational angle or wire insertion angle. The increasing slope of moment in the eccentric hole group was significantly higher than that in the centric hole group. Although the maximum Von-Mises stress was higher in the eccentric hole group, the distribution of stress was not very different from the centric hole group. As the positive wire insertion angles generated a higher moment under a counter-clockwise rotational force, it is recommended to place the head hole consid-ering the implanting direction of the miniscrew. Clinically, multidirectional and higher forces can be applied to the miniscrew with an eccentric head hole position.

Bibliographic Details

Choi, Jin-Young; Kim, Min-Jung; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

MDPI AG

Chemistry; Computer Science; Physics and Astronomy; Biochemistry, Genetics and Molecular Biology; Engineering

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know