Bridgman-Grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A Comparison of Suitability for X and Gamma Detectors
Sensors, ISSN: 1424-8220, Vol: 24, Issue: 2
2024
- 2Captures
- 2Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
- Mentions2
- Blog Mentions1
- Blog1
- News Mentions1
- 1
Most Recent News
Polish Academy of Sciences Reports Findings in Sensor Research [Bridgman-Grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A Comparison of Suitability for X and Gamma Detectors]
2024 FEB 02 (NewsRx) -- By a News Reporter-Staff News Editor at Tech Daily News -- New research on Technology - Sensor Research is the
Article Description
This study explores the suitability of (Cd,Mn)Te and (Cd,Mn)(Te,Se) as room-temperature X-ray and gamma-ray detector materials, grown using the Bridgman method. The investigation compares their crystal structure, mechanical and optical properties, and radiation detection capabilities. Both crystals can yield large-area single crystal samples measuring approximately 30 × 30 mm. In low-temperature photoluminescence analysis, both materials showed defect states, and annealing in cadmium vapors effectively eliminated donor–acceptor pair luminescence in (Cd,Mn)Te but not in (Cd,Mn)(Te,Se). Moreover, harder (Cd,Mn)(Te,Se) exhibited a higher etch pit density compared to softer (Cd,Mn)Te. X-ray diffraction examination revealed uniform lattice constant distribution in both compounds, with variations at a part per million level. (Cd,Mn)Te crystals demonstrated excellent single crystal properties with narrower omega scan widths, while (Cd,Mn)(Te,Se) exhibited a high contribution of block-like structures with significantly larger misorientation angles. Spectroscopic evaluations revealed better performance of a pixelated (Cd,Mn)Te detector, in comparison to (Cd,Mn)(Te,Se), achieving a mean full width at half maximum of 14% for the 122 keV gamma peak of Co-57. The reduced performance of the (Cd,Mn)(Te,Se) detector may be attributed to deep trap-related luminescence or block-like structures with larger misorientation angles. In conclusion, Bridgman-grown (Cd,Mn)Te emerges as a more promising material for X-ray and gamma-ray detectors when compared to (Cd,Mn)(Te,Se).