Effect of Sonication Batch on Electrical Properties of Graphitic-Based PVDF-HFP Strain Sensors for Use in Health Monitoring
Sensors, ISSN: 1424-8220, Vol: 24, Issue: 6
2024
- 2Citations
- 6Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Most Recent Blog
Sensors, Vol. 24, Pages 2007: Effect of Sonication Batch on Electrical Properties of Graphitic-Based PVDF-HFP Strain Sensors for Use in Health Monitoring
Sensors, Vol. 24, Pages 2007: Effect of Sonication Batch on Electrical Properties of Graphitic-Based PVDF-HFP Strain Sensors for Use in Health Monitoring Sensors doi: 10.3390/s24062007
Article Description
In this study, flexible nanocomposites made from PVDF-HFP reinforced with carbon nanotubes (CNTs) and graphene nanoplatelets (GNPs) are manufactured using a sonication and solvent casting method for monitoring purposes. More specifically, the effect of the volume batch under the sonication process is explored. For CNT-based composites, the electrical conductivity decreases as the batch volume increases due to less effective dispersion of the CNTs during the 30-min sonication. The maximum electrical conductivity achieved in this type of sensor is 1.44 ± 0.17 S/m. For the GNP-based nanocomposites, the lower the batch volume is, the more breakage of nanoplatelets is induced by sonication, and the electrical response decreases. This is also validated by AC analysis, where the characteristic frequencies are extracted. Here, the maximum electrical conductivity measured is 8.66 ± 1.76 S/m. The electromechanical results also show dependency on the batch volume. In the CNT-based nanocomposites, the higher gauge factor achieved corresponds to the batch size, where the sonication may be more effective because it leads to a dispersed pathway formed by aggregates connected by tunneling mechanisms. In contrast, in the CNT-based nanocomposites, the GF depends on the lateral size of the GNPs. The biggest GF of all sensors is achieved with the PVDF-HFP/GNP sensors, having a value of 69.36 × 10 at 35% of strain, while the highest GF achieved with a PVDF-HFP/CNT sensor is 79.70 × 10 at 70%. In addition, cycling tests show robust electromechanical response with cycling for two different strain percentages for each type of nanocomposite. The sensor with the highest sensitivity is selected for monitoring two joint movements as proof of the applicability of the sensors manufactured.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know