Design of 1 280×1 024 vertical antiblooming EMCCD
Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, ISSN: 1007-2276, Vol: 50, Issue: 11
2021
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
Article Description
1280×1024 EMCCD is a solid-state low light level imaging device with interline transfer structure. It has the ability of all-time imaging and detection from starlight to sunlight environment. It can be widely used in space remote sensing, visual perception and manless driving. However, due to the limitation of device saturation output, when the incident light intensity is too high for EMCCD, blooming takes place, resulting in the reduction of image resolution and affecting the ability of EMCCD to obtain target information. In order to improve the environmental adaptability of EMCCD and avoid the occurrence of blooming, the causes of EMCCD blooming was analyzed, the working principle of vertical antiblooming was introduced, EMCCD pixels with vertical antiblooming structure were designed through theoretical derivation, analysis and numerical simulation, and a 1280×1024 EMCCD device and principle demonstration prototype with vertical antiblooming function were produced. The simulation data and test results show that the vertical antiblooming EMCCD designed in this paper has 500 times antiblooming ability.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85120524665&origin=inward; http://dx.doi.org/10.3788/irla20210083; http://www.opticsjournal.net/Articles/Abstract/irla/50/11/20210083.cshtml; http://sciencechina.cn/gw.jsp?action=cited_outline.jsp&type=1&id=7105577&internal_id=7105577&from=elsevier
Shanghai Institute of Optics and Fine Mechanics
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know