Corneal volume measurements with pentacam for detection of keratoconus and subclinical keratoconus
Turk Oftalmoloiji Dergisi, ISSN: 1300-0659, Vol: 43, Issue: 2, Page: 77-82
2013
- 3Citations
- 4Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Purpose: To estimate the sensitivity and specificity of corneal volume (CV) measurements in discriminating keratoconus and subclinical keratoconus from normal corneas. Material and Method: Clinical records and Pentacam measurements of ninety-four patients with keratoconus, 36 patients with subclinical keratoconus, and 166 refractive surgery candidates with normal corneas were evaluated retrospectively. CV within 3, 5, 7, and 10 mm circles around the central cornea was measured in one eye of each patient, using the Pentacam. CV measurements in keratoconus and subclinical keratoconus were compared with normal corneas. Receiver operating characteristic (ROC) curves were used to determine the test's overall predictive accuracy and to identify optimal CV cutoff points to maximize sensitivity and specificity in discriminating keratoconus and subclinical keratoconus from normal corneas. Results: Mean CV within a 3.0 mm circle around the central cornea was statistically lower in keratoconus (3.4±0.2 mm, p<0.001) and 33 subclinical keratoconus (3.6±0.2mm, p<0.001) versus normal corneas (3.8±0.3mm). ROC curve analysis showed high overall predictive 33 accuracy of CV for keratoconus (area under the curve 0.92). Optimal cutoff points were 3.55 mm for keratoconus and 3.65 mm for subclinical keratoconus. These values provided sensitivity and specificity of 83% and 86%, respectively, for keratoconus, and 61% and 74% for subclinical keratoconus. Discussion: CV within a 3.0 mm circle around the central cornea effectively discriminates keratoconus from normal corneas. However, its sensitivity and specificity are lower for subclinical keratoconus diagnosis.