In vitro air removal characteristics of two neonatal cardiopulmonary bypass systems: Filtration may lead to fractionation of bubbles
International Journal of Artificial Organs, ISSN: 1724-6040, Vol: 37, Issue: 9, Page: 688-696
2014
- 7Citations
- 19Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations7
- Citation Indexes7
- CrossRef7
- Captures19
- Readers19
- 19
Article Description
Overall, we conclude that both CPB systems were very adequate in removing GME and gross air. The air removal properties of both systems are considered safe and reliable. Detailed GME distribution data show that the Capiox FX05 showed more small GME (<50 μm) due to fractionation of larger GME when compared to the QUADROX-i Neonatal. We may conclude that filtration may lead to fractionation. Introduction of gaseous microemboli (GME) into the arterial line of a pediatric cardiopulmonary bypass (CPB) circuit may lead to cognitive decline and adverse outcomes of the pediatric patient. Arterial filters are incorporated into CPB circuits as a safeguard for gross air and to reduce GME. Recently, arterial filters were integrated in two neonatal oxygenators to reduce volume and foreign surface area. In this study a clinical CPB scenario was simulated. The oxygenators, the corresponding venous reservoirs and the complete CPB circuits were compared regarding air removal and bubble size distribution after the introduction of an air bolus or GME. During a GME challenge, the Capiox FX05 oxygenator removed a significantly higher volume of GME than the QUADROX-i Neonatal oxygenator (97% vs. 86%). Detailed air removal characteristics showed that more GME in the range of 20-50 μm were leaving the devices than were entering. This phenomenon seems to be more present in the Capiox FX05. The circuits were also challenged with an air bolus. Each individual component tested removed 99.9%, which resulted in an air volume reduction of 99.99% by either complete CBP circuit.