PlumX Metrics
Embed PlumX Metrics

Evaluation of setup errors of immobilization device for radiation therapy in companion animals

Open Veterinary Journal, ISSN: 2218-6050, Vol: 12, Issue: 6, Page: 929-935
2022
  • 1
    Citations
  • 0
    Usage
  • 4
    Captures
  • 1
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

  • Citations
    1
    • Citation Indexes
      1
  • Captures
    4
  • Mentions
    1
    • News Mentions
      1
      • 1

Most Recent News

Okayama University Medical School Reports Findings in Veterinary Research (Evaluation of setup errors of immobilization device for radiation therapy in companion animals)

2023 JAN 31 (NewsRx) -- By a News Reporter-Staff News Editor at Daily Veterinary News -- New research on Veterinary Research is the subject of

Article Description

Background: Intensity-modulated radiotherapy (IMRT), which allows generating steep dose gradients, is a beneficial treatment for companion animals with adjacent target and risk organs. IMRT is essential for high setup accuracy for avoiding overdose to risk organs, and optimal radiotherapy is important for evaluating the setup accuracy of companion animals. Aim: To use an immobilization device to evaluate setup errors in radiotherapy for companion animals. Methods: We calculated setup errors in radiotherapy for 386 animals (dogs and cats; 3,261 registration images) that underwent radiotherapy between 2016 and 2022. The companion animals were immobilized with a customized bite block and vacuum lock device. A quantile–quantile plot with 95% confidence interval (CI) was used to evaluate the histogram of the setup errors, and the systematic and random setup errors were calculated for each region (brain, head and neck, chest and abdomen, pelvis, and spine). Results: The setup error in each direction presented an extremely narrow-interval histogram, with the following lower and upper 95% CIs: cranial–caudal (−0.08, −0.06 cm); left–right (−0.04, −0.02 cm); and dorsal–ventral (−0.13, −0.11 cm). The mean systematic setup error was 0.16 cm (range: 0.12–0.36 cm), and the random error was 0.15 cm (range: 0.08–0.34 cm). The pelvis showed the highest systematic and random setup errors (mean: 0.36 and 0.23 cm, respectively). Conclusion: The use of an immobilization device enables highly accurate radiotherapy for companion animals (95% CI < 0.15 cm).

Bibliographic Details

Iseri, Toshie; Hira, Nanami; Tanabe, Yoshinori; Horikirizono, Hiro; Sunahara, Hiroshi; Itoh, Harumichi; Nemoto, Yuki; Itamoto, Kazuhito; Tani, Kenji; Nakaichi, Munekazu

ScopeMed

Veterinary

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know