[Measurement Accuracy of CT Beam Width with a Portable Flat-panel Detector].
Nihon Hoshasen Gijutsu Gakkai zasshi, ISSN: 0369-4305, Vol: 76, Issue: 2, Page: 161-167
2020
- 1Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures1
- Readers1
Article Description
X-ray film or computed radiography (CR) system has been employed in clinical setting, and these devices are gradually replaced by portable flat-panel detector (FPD) systems. They may be employed to measure the beam width instead of the traditional CR system. In this study, we estimated the accuracy of beam width measured by the portable FPD system.
Bibliographic Details
http://www.ncbi.nlm.nih.gov/pubmed/32074524; http://dx.doi.org/10.6009/jjrt.2020_jsrt_76.2.161; https://www.jstage.jst.go.jp/article/jjrt/76/2/76_2020_JSRT_76.2.161/_article/-char/ja/; https://www.jstage.jst.go.jp/article/jjrt/76/2/76_2020_JSRT_76.2.161/_article/-char/en/; https://dx.doi.org/10.6009/jjrt.2020_jsrt_76.2.161