Experimental study of insulated aluminum planar wire array Z pinches
Wuli Xuebao/Acta Physica Sinica, ISSN: 1000-3290, Vol: 63, Issue: 5, Page: 055201-null
2014
- 9Citations
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations9
- Citation Indexes9
- CrossRef3
- Captures2
- Readers2
Article Description
The planar wire array Z pinch experiments with insulated aluminum wires coated with 2 μm polyimide were carried out on "QiangGuang-I" facility (100 ns, 1.3 MA) and compared to those with ordinary aluminum wires. Experimental results indicate that surface insulation can affect the implosion dynamics and radiation character of Z pinches. The resistive heating energy and imploding mass may be increased by exploiting the effect of surface insulation. In the surface-insulated wire array Z pinch experiments the multi-peak phenomena were considerably suppressed, whereas the improvement on the X-ray yield was not observed. © 2014 Chinese Physical Society.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84896035307&origin=inward; http://dx.doi.org/10.7498/aps.63.055201; https://wulixb.iphy.ac.cn/article/doi/10.7498/aps.63.055201; https://dx.doi.org/10.7498/aps.63.055201; http://sciencechina.cn/gw.jsp?action=cited_outline.jsp&type=1&id=5081139&internal_id=5081139&from=elsevier
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know