Effects of the curve type of overcurrent functions and the location of analyzed faults on the optimal coordination of directional overcurrent protections
Computers & Electrical Engineering, ISSN: 0045-7906, Vol: 88, Page: 106864
2020
- 11Citations
- 15Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The time-current curve type and the considered fault locations influence the optimal coordination of directional overcurrent protections. It is shown that curve type can determine the feasibility of having solutions and the feasibility of obtaining reasonably low trip times. It is also shown that constraints for faults near to the main relay location must be complemented with those of other fault locations. In general, the use of Extremely Inverse curves implies a faster protection in the analyzed cases. This is because this coordination depends on the ratio between the currents seen by each relay, and Extremely Inverse curves have the greatest inclination in time-current graphs. The backup action for faults near to the remote line end of main relays can be very slow with Extremely Inverse curves in some cases; therefore, an analysis of benefits and drawbacks of using each curve type should be performed in each analyzed case.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0045790620307175; http://dx.doi.org/10.1016/j.compeleceng.2020.106864; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85095723159&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0045790620307175; https://dx.doi.org/10.1016/j.compeleceng.2020.106864
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know