Biomechanical study of proximal femur for designing stems for total hip replacement
Applied Sciences (Switzerland), ISSN: 2076-3417, Vol: 10, Issue: 12, Page: 1-17
2020
- 14Citations
- 49Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Innovative hip implants should be designed in accordance with biomechanical models of the proximal femur and take into account both body weight and muscle action in order to improve usability and biomimetic performance. This article proposes a finite element analysis of the proximal femur using both cortical and trabecular regions and employing transverse isotropic properties with standardized loads taken from active and young patients. Maximum principal stresses are plotted to show the mechanical behavior of the femur and grouped to evaluate stress shielding. Tsai-Wu and the maximum principal stress fields are useful for finding the areas more prone to failure and analyzing the influence of the stems on femoral mechanics. Other parameters, such as the stem material, absence of neck and osteotomy level, are explained. This paper is expected to provide a guide for designers and surgeons of femoral stems for assessing qualitatively and quantitatively the risks of stress shielding.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know